Product Show
Click here for helps
fsxunlian@hotmail.com
| Technical note: * Impedance of 75¦¸ * Conductor use of single-or multi-stranded bare copper wire * Solid polyolefin insulation * Aluminum foil shield * Soft copper or tinning soft copper braided shield * Appropriate at -25¡æ ~ -70¡æ under the conditions of use Implementation of the standards:GB/T 14864-1993 |
| Model | Conductor structure N0./mm | Insulation thickness | Conductor | Jacket | |||
| Thickness(mm) | Diameter(mm) | Braid net No. | Density reference value | Thickness(mm) | Diameter(mm) | ||
| SYV50-2-1 | 7/0.16 | 0.44 | 1.5¡À0.1 | 48 | 70% | 0.43 | 2.8¡À0.2 |
| 64 | 85% | 0.43 | 2.8¡À0.2 | ||||
| 96 | 95% | 0.43 | 2.8¡À0.2 | ||||
| SYV50-2-41 | 1/0.68 | 0.65 | 2.2¡À0.1 | 48 | 65% | 0.56 | 4.0¡À0.2 |
| 64 | 75% | 0.56 | 4.0¡À0.2 | ||||
| 96 | 90% | 0.56 | 4.0¡À0.2 | ||||
| SYV50-3-1 | 7/0.32 | 0.8 | 2.95¡À0.13 | 64 | 60% | 0.75 | 5.0¡À0.2 |
| 96 | 80% | 0.75 | 5.0¡À0.2 | ||||
| 128 | 90% | 0.75 | 5.0¡À0.2 | ||||
| SYV50-3-4 | 1/0.9 | 0.85 | 2.95¡À0.13 | 64 | 60% | 0.75 | 5.0¡À0.2 |
| 96 | 80% | 0.75 | 5.0¡À0.2 | ||||
| 128 | 90% | 0.75 | 5.0¡À0.2 | ||||
| SYV50-4-1 | 19/0.18 | 0.8 | 2.95¡À0.13 | 64 | 60% | 0.75 | 5.0¡À0.2 |
| 96 | 80% | 0.75 | 5.0¡À0.2 | ||||
| 128 | 90% | 0.75 | 5.0¡À0.2 | ||||
| SYV50-5-1 | 1/1.4 | 1.3 | 4.8¡À0.2 | 64 | 45% | 0.88 | 7.2¡À0.3 |
| 96 | 65% | 0.88 | 7.2¡À0.3 | ||||
| 128 | 80% | 0.88 | 7.2¡À0.3 | ||||
| SYV50-7-2 | 7/0.75 | 2 | 7.25¡À0.25 | 96 | 55% | 1.05 | 10.3¡À0.3 |
| 128 | 65% | 1.05 | 10.3¡À0.3 | ||||
| 144 | 75% | 1.05 | 10.3¡À0.3 | ||||
| SYV50-9-41 | 7/0.95 | 2.6 | 9.0¡À0.3 | 96 | 45% | 1.18 | 12.2¡À0.4 |
| 128 | 50% | 1.18 | 12.2¡À0.4 | ||||
| 144 | 60% | 1.18 | 12.2¡À0.4 | ||||
| Model | Attenuation constant 20¡æ dB/100m | DB return loss | |||||||
| 1MHz | 5MHz | 20MHz | 50MHz | 200MHz | 400MHz | 900MHz | ¡Ü300MHz | £¾300MHz | |
| SYV50-2-1 | 2.20 | 4.50 | 12.50 | 20.00 | 40.00 | 60.00 | 83.00 | 22.00 | 20.00 |
| SYV50-2-41 | 2.00 | 4.30 | 9.00 | 13.00 | 30.00 | 42.50 | 65.00 | 22.00 | 20.00 |
| SYV50-3-1 | 1.80 | 4.00 | 6.20 | 12.30 | 22.50 | 32.50 | 45.00 | 22.00 | 20.00 |
| SYV50-3-4 | 1.80 | 4.20 | 8.20 | 12.20 | 22.50 | 33.50 | 47.80 | 22.00 | 20.00 |
| SYV50-4-1 | 1.80 | 4.00 | 6.20 | 12.30 | 22.50 | 32.50 | 45.00 | 22.00 | 20.00 |
| SYV50-5-1 | 1.00 | 2.90 | 3.90 | 6.20 | 13.00 | 19.00 | 30.00 | 22.00 | 20.00 |
| SYV50-7-2 | 0.80 | 2.20 | 2.90 | 4.90 | 10.50 | 16.00 | 24.00 | 20.00 | 18.00 |
| SYV50-9-41 | 0.60 | 1.70 | 2.50 | 4.20 | 9.50 | 14.00 | 23.00 | 20.00 | 18.00 |
| Model | conductor resistance (20 ¡æ)Max | Core cable dielectric strength kV | Insulation resistance (Min) M ¦¸ km | Dielectric strength of jacket kV | Impedance ¦¸ | |
| Sparks test | Water test | |||||
| SYV50-2-1 | 120.50 | 2.0 | 5000 | / | / | 50¡À2 |
| SYV50-2-41 | 48.20 | 3.0 | 5000 | 3.0 | 2.0 | 50¡À2 |
| SYV50-3-1 | 40.10 | 4.0 | 5000 | 3.0 | 2.0 | 50¡À2 |
| SYV50-3-4 | 24.50 | 4.0 | 5000 | 3.0 | 2.0 | 50¡À2 |
| SYV50-4-1 | 42.80 | 4.0 | 5000 | 3.0 | 2.0 | 50¡À2 |
| SYV50-5-1 | 13.30 | 6.5 | 5000 | 5.0 | 3.0 | 50¡À2 |
| SYV50-7-2 | 6.20 | 10.0 | 5000 | 8.0 | 5.0 | 50¡À2 |
| SYV50-9-41 | 3.85 | 12.0 | 5000 | 8.0 | 5.0 | 50¡À2 |