RVV 300/500V Copper core PVC jacket soft PVC insulated cables
Form : http://www.chinadropwire.com/ Author: Time:2008-12-24 18:19:54RVV 300/500V Copper core PVC jacket soft PVC insulated cables
|
Cores x sq. |
Insulation thickness (mm) |
Jacket thickness |
Average size(mm) |
Min. insulation resistance at 70℃ | |
|
Min. |
Max. | ||||
|
2×2.0 |
0.8 |
0.8 |
7.2 |
10.0 |
0.0090 |
|
3×2.0 |
0.8 |
0.8 |
7.7 |
10.5 |
0.0090 |
|
4×2.0 |
0.8 |
0.8 |
8.6 |
11.4 |
0.0090 |
|
5×2.0 |
0.8 |
1.1 |
10.2 |
13.0 |
0.0090 |
|
6×1.0 |
0.6 |
1.2 |
8.8 |
11.6 |
0.0100 |
|
6×1.5 |
0.7 |
1.2 |
10.0 |
12.8 |
0.0090 |
|
6×2.0 |
0.8 |
1.2 |
11.4 |
14.2 |
0.0090 |
|
6×2.5 |
0.8 |
1.2 |
12.3 |
15.1 |
0.0090 |
|
7×1.0 |
0.6 |
1.2 |
8.8 |
11.6 |
0.0100 |
|
7×1.5 |
0.7 |
1.2 |
10.0 |
12.8 |
0.0090 |
|
7×2.0 |
0.8 |
1.2 |
11.4 |
14.2 |
0.0090 |
|
7×2.5 |
0.8 |
1.2 |
12.3 |
15.1 |
0.0090 |
|
8×1.0 |
0.6 |
1.2 |
9.5 |
12.3 |
0.0100 |
|
8×1.5 |
0.7 |
1.2 |
10.9 |
13.7 |
0.0090 |
|
8×2.0 |
0.8 |
1.2 |
12.5 |
15.3 |
0.0090 |
|
8×2.5 |
0.8 |
1.2 |
13.4 |
16.2 |
0.0090 |
|
9×1.0 |
0.6 |
1.2 |
10.6 |
13.4 |
0.0100 |
|
9×1.5 |
0.7 |
1.2 |
12.1 |
14.9 |
0.0090 |
|
9×2.0 |
0.8 |
1.2 |
13.8 |
16.6 |
0.0090 |
|
9×2.5 |
0.8 |
1.2 |
14.8 |
17.6 |
0.0090 |
|
10×1.0 |
0.6 |
1.2 |
11.3 |
14.1 |
0.0100 |
|
10×1.5 |
0.7 |
1.2 |
13.0 |
15.8 |
0.0090 |
|
10×2.0 |
0.8 |
1.2 |
14.9 |
17.7 |
0.0090 |
|
10×2.5 |
0.8 |
1.2 |
16.0 |
18.8 |
0.0090 |
|
11×1.0 |
0.6 |
1.2 |
11.7 |
14.5 |
0.0100 |
|
11×1.5 |
0.7 |
1.2 |
13.4 |
16.2 |
0.0090 |
|
11×2.0 |
0.8 |
1.2 |
15.4 |
18.2 |
0.0090 |
|
11×2.5 |
0.8 |
1.2 |
16.5 |
19.3 |
0.0090 |
|
12×1.0 |
0.6 |
1.2 |
11.7 |
14.5 |
0.0100 |
|
12×1.5 |
0.7 |
1.2 |
13.4 |
16.2 |
0.0090 |
|
12×2.0 |
0.8 |
1.2 |
15.4 |
18.2 |
0.0090 |
|
12×2.5 |
0.8 |
1.2 |
16.5 |
19.3 |
0.0090 |
|
13×1.0 |
0.6 |
1.2 |
12.4 |
15.2 |
0.0100 |
|
13×1.5 |
0.7 |
1.2 |
14.2 |
17.0 |
0.0090 |
|
13×2.0 |
0.8 |
1.2 |
16.3 |
19.4 |
0.0090 |
|
13×2.5 |
0.8 |
1.2 |
17.5 |
20.3 |
0.0090 |
|
14×1.0 |
0.6 |
1.2 |
12.4 |
15.2 |
0.0100 |
|
14×1.5 |
0.7 |
1.2 |
14.2 |
17.0 |
0.0090 |
|
14×2.0 |
0.8 |
1.2 |
16.3 |
19.1 |
0.0090 |
|
14×2.5 |
0.8 |
1.2 |
17.5 |
20.3 |
0.0090 |
|
15×1.0 |
0.6 |
1.2 |
13.1 |
15.9 |
0.0100 |
|
15×1.5 |
0.7 |
1.2 |
15.0 |
17.8 |
0.0090 |
|
15×2.0 |
0.8 |
1.2 |
17.3 |
20.1 |
0.0090 |
|
15×2.5 |
0.8 |
1.2 |
18.5 |
21.3 |
0.0090 |
|
16×1.0 |
0.6 |
1.2 |
13.1 |
15.9 |
0.0100 |
|
16×1.5 |
0.7 |
1.2 |
14.5 |
17.3 |
0.0090 |
|
16×2.0 |
0.8 |
1.2 |
17.3 |
20.1 |
0.0090 |
|
16×2.5 |
0.8 |
1.2 |
18.5 |
21.3 |
0.0090 |
|
18×1.0 |
0.6 |
1.2 |
13.9 |
16.7 |
0.0100 |
|
18×1.5 |
0.7 |
1.2 |
15.9 |
18.7 |
0.0090 |
|
18×2.0 |
0.8 |
1.2 |
18.3 |
21.1 |
0.0090 |
|
18×2.5 |
0.8 |
1.2 |
19.7 |
22.5 |
0.0090 |
|
19×1.0 |
0.6 |
1.2 |
13.9 |
16.7 |
0.0100 |
|
19×1.5 |
0.7 |
1.2 |
15.9 |
18.7 |
0.0090 |
|
19×2.0 |
0.8 |
1.2 |
18.3 |
21.1 |
0.0090 |
|
19×2.5 |
0.8 |
1.2 |
19.7 |
22.5 |
0.0090 |
|
20×1.0 |
0.6 |
1.2 |
14.2 |
17.0 |
0.0100 |
|
20×1.5 |
0.7 |
1.2 |
16.4 |
19.2 |
0.0090 |
|
20×2.0 |
0.8 |
1.2 |
18.8 |
21.6 |
0.0090 |
|
20×2.5 |
0.8 |
1.2 |
20.2 |
23.0 |
0.0090 |
|
22×1.0 |
0.6 |
1.2 |
15.6 |
18.4 |
0.0100 |
|
22×1.5 |
0.7 |
1.2 |
18.0 |
20.7 |
0.0090 |
|
22×2.0 |
0.8 |
1.2 |
20.7 |
23.5 |
0.0090 |
|
22×2.5 |
0.8 |
1.2 |
22.2 |
25.0 |
0.0090 |
|
24×1.0 |
0.6 |
1.2 |
16.4 |
19.2 |
0.0100 |
|
24×1.5 |
0.7 |
1.2 |
18.9 |
21.7 |
0.0090 |
|
24×2.0 |
0.8 |
1.2 |
21.7 |
24.5 |
0.0090 |
|
24×2.5 |
0.8 |
1.2 |
23.4 |
26.2 |
0.0090 |
RVV
Statement:
* conductor for the multi-annealing bare copper or tin plated copper strands
* PVC insulation
* PVC jacket
* film around the moisture-proof package
* tin copper braided shield
Use occasions:
This applies to the wild product lines. Electrical Instrument telecommunications broadcasting, electronic equipment and automation devices, such as shielding lines.
The use of temperature:
The length of wire to allow temperature is more than 70 ℃
The laying of the cable, not lower than the temperature of -15 ℃
Relative Humidity: 98%
Main technical parameters
* rated voltage (AC 50 Hz): 380V DC:500V
* test voltage (AC 50 Hz): 2000V
* insulation resistance (20℃): not less than 2MΩkm
* braided wire and cable general density of not less than 80 percent
Implementation of the standards:
Model:
227 IEC 08 RVS
227 IEC 08 RV-90
RVV 300/300V
227 IEC 52 RVV 300/300V
227 IEC 53 RVV 300/300V
RVV 300/500V -01
RVV 300/500V -02
light type PVC jacket soft wire
common type PVC jacket soft wire