Here: Homepage -> Customer Service -> Cable Technology -> AVRS Copper core PVC insulated cables technical parameters

AVRS Copper core PVC insulated cables technical parameters

Form : http://www.chinadropwire.com/  Author:  Time:2008-12-25 10:04:28

AVRS Copper core PVC insulated cables technical parameters

SQ.
(mm2)

Max. Diameter
(mm)

Insulation thickness(mm)

average OD
(mm)

Resistance at 20¡æ
(¦¸/km)

Min. insulation resistance 70¡æ
(M¦¸¡¤km)

Copper

Tinned copper

2¡Á0.12

0.16

0.5

3.4

158

163

0.018

2¡Á0.2

0.16

0.6

4.2

92.3

95

0.017

2¡Á0.3

0.16

0.6

4.4

69.2

71.2

0.016

2¡Á0.4

0.16

0.6

4.8

48.2

49.6

0.014

Statement: 
* conductor for the multi-annealing bare copper or tin plated copper strands
* PVC insulation
* PVC jacket
* film around the moisture-proof package
* tin copper braided shield

Use: 
 This applies to the wild product lines. Electrical Instrument telecommunications broadcasting, electronic equipment and automation devices, such as shielding lines.

The use of temperature:
* The length of wire to allow temperature is more than 70 ¡æ 
* The laying of the cable, not lower than the temperature of -15 ¡æ 
* Relative Humidity: 98%

Main technical parameters:
* rated voltage (AC 50 Hz): 380V DC: 500 V
* test voltage (AC 50 Hz): 2000V
* insulation resistance (20 ¡æ): not less than 2 M ¦¸ km
* braided wire and cable general density of not less than 80 percent

Implementation of the standards: 
 JB 8734-1998   JIS C3662   
 JB 5023-1997   DIN VDE 0281   
 EC 227 

Other Models:
1.AVVR structural parameters
2.AVVR-300/300V Copper core PVC insulated cables
3.AVPV / SBVVP Copper core PVC insulated cables
4.AVPV SBVVP Copper core PVC insulated cables
5.AVR Copper core PVC insulated cables