AVRS Copper core PVC insulated cables technical parameters
Form : http://www.chinadropwire.com/ Author: Time:2008-12-25 10:04:28
|
SQ. |
Max. Diameter |
Insulation thickness(mm) |
average OD |
Resistance at 20¡æ |
Min. insulation resistance 70¡æ | |
|
Copper |
Tinned copper | |||||
|
2¡Á0.12 |
0.16 |
0.5 |
3.4 |
158 |
163 |
0.018 |
|
2¡Á0.2 |
0.16 |
0.6 |
4.2 |
92.3 |
95 |
0.017 |
|
2¡Á0.3 |
0.16 |
0.6 |
4.4 |
69.2 |
71.2 |
0.016 |
|
2¡Á0.4 |
0.16 |
0.6 |
4.8 |
48.2 |
49.6 |
0.014 |
* conductor for the multi-annealing bare copper or tin plated copper strands
* PVC insulation
* PVC jacket
* film around the moisture-proof package
* tin copper braided shield
Use:
This applies to the wild product lines. Electrical Instrument telecommunications broadcasting, electronic equipment and automation devices, such as shielding lines.
The use of temperature:
* The length of wire to allow temperature is more than 70 ¡æ
* The laying of the cable, not lower than the temperature of -15 ¡æ
* Relative Humidity: 98%
Main technical parameters:
* rated voltage (AC 50 Hz): 380V DC: 500 V
* test voltage (AC 50 Hz): 2000V
* insulation resistance (20 ¡æ): not less than 2 M ¦¸ km
* braided wire and cable general density of not less than 80 percent
Implementation of the standards:
JB 8734-1998 JIS C3662
JB 5023-1997 DIN VDE 0281
EC 227
Other Models:
1.AVVR structural parameters
2.AVVR-300/300V Copper core PVC insulated cables
3.AVPV / SBVVP Copper core PVC insulated cables
4.AVPV SBVVP Copper core PVC insulated cables