AVVR-300/300V Copper core PVC insulated cables technical parameters
Form : http://www.chinadropwire.com/ Author: Time:2008-12-25 10:09:09AVVR-300/300V Copper core PVC insulated cables technical parameters
|
Cores× Sq. |
Max. diameter of the conducor |
Iinsulation thickness |
Jacket thickness |
Average OD (mm) |
Resistance at 20℃(Ω/km) |
Min. insulation resistance at 70℃ | ||
|
MAX. |
MIN. |
Copper |
Tinned copper | |||||
|
2×0.08 |
0.13 |
0.4 |
0.6 |
3.1 |
4.1 |
247 |
254 |
0.018 |
|
2×0.12 |
0.16 |
0.4 |
0.6 |
3.3 |
4.3 |
158 |
163 |
0.016 |
|
2×0.2 |
0.16 |
0.4 |
0.6 |
3.6 |
4.7 |
92.3 |
95 |
0.014 |
|
2×0.3 |
0.16 |
0.5 |
0.6 |
4.1 |
5.3 |
69.2 |
71.2 |
0.014 |
|
2×0.4 |
0.16 |
0.5 |
0.6 |
4.4 |
5.7 |
48.2 |
49.6 |
0.013 |
|
3×0.12 |
0.16 |
0.4 |
0.6 |
3.4 |
4.5 |
158 |
163 |
0.016 |
|
3×0.2 |
0.16 |
0.4 |
0.6 |
3.8 |
4.9 |
92.3 |
95 |
0.014 |
|
3×0.3 |
0.16 |
0.5 |
0.6 |
4.4 |
5.7 |
69.2 |
71.2 |
0.014 |
|
3×0.4 |
0.16 |
0.5 |
0.6 |
4.7 |
6.0 |
48.2 |
49.6 |
0.013 |
|
4×0.12 |
0.16 |
0.4 |
0.6 |
3.8 |
4.9 |
158 |
163 |
0.016 |
|
4×0.2 |
0.16 |
0.4 |
0.6 |
4.2 |
5.4 |
92.3 |
95 |
0.014 |
|
4×0.3 |
0.16 |
0.5 |
0.6 |
4.8 |
6.2 |
69.2 |
71.2 |
0.014 |
|
4×0.4 |
0.16 |
0.5 |
0.6 |
5.1 |
6.6 |
48.2 |
49.6 |
0.013 |
|
5×0.12 |
0.16 |
0.4 |
0.6 |
4.1 |
5.3 |
158 |
163 |
0.016 |
|
5×0.2 |
0.16 |
0.4 |
0.6 |
4.5 |
5.8 |
92.3 |
95 |
0.014 |
|
5×0.3 |
0.16 |
0.5 |
0.6 |
5.3 |
6.7 |
69.2 |
71.2 |
0.014 |
|
5×0.4 |
0.16 |
0.5 |
0.6 |
5.6 |
7.2 |
48.2 |
49.6 |
0.013 |
|
6~7×0.12 |
0.16 |
0.4 |
0.6 |
4.4 |
5.7 |
158 |
163 |
0.016 |
|
6~7×0.2 |
0.16 |
0.4 |
0.6 |
4.9 |
6.3 |
92.3 |
95 |
0.014 |
|
6~7×0.3 |
0.16 |
0.5 |
0.6 |
5.7 |
7.3 |
69.2 |
71.2 |
0.014 |
|
6~7×0.4 |
0.16 |
0.5 |
0.6 |
6.2 |
7.8 |
48.2 |
49.6 |
0.013 |
|
10×0.12 |
0.16 |
0.4 |
0.6 |
5.7 |
7.2 |
158 |
163 |
0.016 |
|
10×0.2 |
0.16 |
0.4 |
0.6 |
6.3 |
8.0 |
92.3 |
95 |
0.014 |
|
10×0.3 |
0.16 |
0.5 |
0.8 |
7.8 |
9.7 |
69.2 |
71.2 |
0.014 |
|
10×0.4 |
0.16 |
0.5 |
0.8 |
8.3 |
10.4 |
48.2 |
49.6 |
0.013 |
|
12×0.12 |
0.16 |
0.4 |
0.6 |
5.8 |
7.4 |
158 |
163 |
0.016 |
|
12×0.2 |
0.16 |
0.4 |
0.6 |
6.5 |
8.2 |
92.3 |
95 |
0.014 |
|
12×0.3 |
0.16 |
0.5 |
0.8 |
8 |
10.1 |
69.2 |
71.2 |
0.014 |
|
12×0.4 |
0.16 |
0.5 |
0.8 |
8.6 |
10.8 |
48.2 |
49.6 |
0.013 |
|
14×0.12 |
0.16 |
0.4 |
0.6 |
6.1 |
7.8 |
158 |
163 |
0.016 |
|
14×0.2 |
0.16 |
0.4 |
0.8 |
7.2 |
9.1 |
92.3 |
95 |
0.014 |
|
14×0.3 |
0.16 |
0.5 |
0.8 |
8.4 |
10.6 |
69.2 |
71.2 |
0.014 |
|
14×0.4 |
0.16 |
0.5 |
0.8 |
9.1 |
11.3 |
48.2 |
49.6 |
0.013 |
|
16×0.12 |
0.16 |
0.4 |
0.6 |
6.5 |
8.2 |
158 |
163 |
0.016 |
|
16×0.2 |
0.16 |
0.4 |
0.8 |
7.6 |
9.6 |
92.3 |
95 |
0.014 |
|
16×0.3 |
0.16 |
0.5 |
0.8 |
8.9 |
11.1 |
69.2 |
71.2 |
0.014 |
|
16×0.4 |
0.16 |
0.5 |
0.8 |
9.6 |
11.9 |
48.2 |
49.6 |
0.013 |
|
19×0.12 |
0.16 |
0.4 |
0.8 |
7.2 |
9.1 |
158 |
163 |
0.016 |
|
19×0.2 |
0.16 |
0.4 |
0.8 |
8.1 |
10.1 |
92.3 |
95 |
0.014 |
|
19×0.3 |
0.16 |
0.5 |
0.8 |
9.4 |
11.7 |
69.2 |
71.2 |
0.014 |
|
19×0.4 |
0.16 |
0.5 |
0.8 |
10.1 |
12.6 |
48.2 |
49.6 |
0.013 |
|
24×0.12 |
0.16 |
0.4 |
0.8 |
8.4 |
10.6 |
158 |
163 |
0.016 |
|
24×0.2 |
0.16 |
0.4 |
0.8 |
9.4 |
11.7 |
92.3 |
95 |
0.014 |
|
24×0.3 |
0.16 |
0.5 |
1.0 |
11.4 |
14.2 |
69.2 |
71.2 |
0.014 |
|
24×0.4 |
0.16 |
0.5 |
1.0 |
12.3 |
15.2 |
48.2 |
49.6 |
0.013 |
* conductor for the multi-annealing bare copper or tin plated copper strands
* PVC insulation
* PVC jacket
* film around the moisture-proof package
* tin copper braided shield
Use:
This applies to the wild product lines. Electrical Instrument telecommunications broadcasting, electronic equipment and automation devices, such as shielding lines.
The use of temperature:
* The length of wire to allow temperature is more than 70 ℃
* The laying of the cable, not lower than the temperature of -15 ℃
* Relative Humidity: 98%
Main technical parameters:
* rated voltage (AC 50 Hz): 380V DC: 500 V
* test voltage (AC 50 Hz): 2000V
* insulation resistance (20 ℃): not less than 2 M Ω km
* braided wire and cable general density of not less than 80 percent
Implementation of the standards:
JB 8734-1998 JIS C3662
JB 5023-1997 DIN VDE 0281
EC 227
Model:
1.AVVR structural parameters
2.AVPV / SBVVP Copper core PVC insulated cables
3.AVPV SBVVP Copper core PVC insulated cables
4.AVR Copper core PVC insulated cables
5.AVRS Copper core PVC insulated cables