Here: Homepage -> Customer Service -> Cable Technology -> AVVR-300/300V Copper core PVC insulated cables technical parameters

AVVR-300/300V Copper core PVC insulated cables technical parameters

Form : http://www.chinadropwire.com/  Author:  Time:2008-12-25 10:09:09

AVVR-300/300V Copper core PVC insulated cables technical parameters

Cores¡Á Sq.
(mm2)

Max. diameter of the conducor
(mm)

Iinsulation thickness
(mm)

Jacket thickness
(mm)

Average OD (mm)

 Resistance at 20¡æ(¦¸/km)

Min. insulation resistance at 70¡æ
(M¦¸¡¤km)

MAX.

MIN.

Copper

Tinned copper

2¡Á0.08

0.13

0.4

0.6

3.1
2.3¡Á3.4

4.1
2.7¡Á4.1

247

254

0.018

2¡Á0.12

0.16

0.4

0.6

3.3
2.4¡Á3.6

4.3
2.8¡Á4.3

158

163

0.016

2¡Á0.2

0.16

0.4

0.6

3.6
2.5¡Á3.9

4.7
3.0¡Á4.7

92.3

95

0.014

2¡Á0.3

0.16

0.5

0.6

4.1
2.5¡Á3.9

5.3
3.4¡Á5.3

69.2

71.2

0.014

2¡Á0.4

0.16

0.5

0.6

4.4
2.9¡Á4.4

5.7
3.5¡Á5.3

48.2

49.6

0.013

3¡Á0.12

0.16

0.4

0.6

3.4

4.5

158

163

0.016

3¡Á0.2

0.16

0.4

0.6

3.8

4.9

92.3

95

0.014

3¡Á0.3

0.16

0.5

0.6

4.4

5.7

69.2

71.2

0.014

3¡Á0.4

0.16

0.5

0.6

4.7

6.0

48.2

49.6

0.013

4¡Á0.12

0.16

0.4

0.6

3.8

4.9

158

163

0.016

4¡Á0.2

0.16

0.4

0.6

4.2

5.4

92.3

95

0.014

4¡Á0.3

0.16

0.5

0.6

4.8

6.2

69.2

71.2

0.014

4¡Á0.4

0.16

0.5

0.6

5.1

6.6

48.2

49.6

0.013

5¡Á0.12

0.16

0.4

0.6

4.1

5.3

158

163

0.016

5¡Á0.2

0.16

0.4

0.6

4.5

5.8

92.3

95

0.014

5¡Á0.3

0.16

0.5

0.6

5.3

6.7

69.2

71.2

0.014

5¡Á0.4

0.16

0.5

0.6

5.6

7.2

48.2

49.6

0.013

6¡«7¡Á0.12

0.16

0.4

0.6

4.4

5.7

158

163

0.016

6¡«7¡Á0.2

0.16

0.4

0.6

4.9

6.3

92.3

95

0.014

6¡«7¡Á0.3

0.16

0.5

0.6

5.7

7.3

69.2

71.2

0.014

6¡«7¡Á0.4

0.16

0.5

0.6

6.2

7.8

48.2

49.6

0.013

10¡Á0.12

0.16

0.4

0.6

5.7

7.2

158

163

0.016

10¡Á0.2

0.16

0.4

0.6

6.3

8.0

92.3

95

0.014

10¡Á0.3

0.16

0.5

0.8

7.8

9.7

69.2

71.2

0.014

10¡Á0.4

0.16

0.5

0.8

8.3

10.4

48.2

49.6

0.013

12¡Á0.12

0.16

0.4

0.6

5.8

7.4

158

163

0.016

12¡Á0.2

0.16

0.4

0.6

6.5

8.2

92.3

95

0.014

12¡Á0.3

0.16

0.5

0.8

8

10.1

69.2

71.2

0.014

12¡Á0.4

0.16

0.5

0.8

8.6

10.8

48.2

49.6

0.013

14¡Á0.12

0.16

0.4

0.6

6.1

7.8

158

163

0.016

14¡Á0.2

0.16

0.4

0.8

7.2

9.1

92.3

95

0.014

14¡Á0.3

0.16

0.5

0.8

8.4

10.6

69.2

71.2

0.014

14¡Á0.4

0.16

0.5

0.8

9.1

11.3

48.2

49.6

0.013

16¡Á0.12

0.16

0.4

0.6

6.5

8.2

158

163

0.016

16¡Á0.2

0.16

0.4

0.8

7.6

9.6

92.3

95

0.014

16¡Á0.3

0.16

0.5

0.8

8.9

11.1

69.2

71.2

0.014

16¡Á0.4

0.16

0.5

0.8

9.6

11.9

48.2

49.6

0.013

19¡Á0.12

0.16

0.4

0.8

7.2

9.1

158

163

0.016

19¡Á0.2

0.16

0.4

0.8

8.1

10.1

92.3

95

0.014

19¡Á0.3

0.16

0.5

0.8

9.4

11.7

69.2

71.2

0.014

19¡Á0.4

0.16

0.5

0.8

10.1

12.6

48.2

49.6

0.013

24¡Á0.12

0.16

0.4

0.8

8.4

10.6

158

163

0.016

24¡Á0.2

0.16

0.4

0.8

9.4

11.7

92.3

95

0.014

24¡Á0.3

0.16

0.5

1.0

11.4

14.2

69.2

71.2

0.014

24¡Á0.4

0.16

0.5

1.0

12.3

15.2

48.2

49.6

0.013

Statement: 
* conductor for the multi-annealing bare copper or tin plated copper strands
* PVC insulation
* PVC jacket
* film around the moisture-proof package
* tin copper braided shield

Use: 
 This applies to the wild product lines. Electrical Instrument telecommunications broadcasting, electronic equipment and automation devices, such as shielding lines.

The use of temperature:
* The length of wire to allow temperature is more than 70 ¡æ 
* The laying of the cable, not lower than the temperature of -15 ¡æ 
* Relative Humidity: 98%

Main technical parameters:
* rated voltage (AC 50 Hz): 380V DC: 500 V
* test voltage (AC 50 Hz): 2000V
* insulation resistance (20 ¡æ): not less than 2 M ¦¸ km
* braided wire and cable general density of not less than 80 percent

Implementation of the standards: 
 JB 8734-1998   JIS C3662   
 JB 5023-1997   DIN VDE 0281   
 EC 227 

Model:
1.AVVR structural parameters
2.AVPV / SBVVP Copper core PVC insulated cables
3.AVPV SBVVP Copper core PVC insulated cables
4.AVR Copper core PVC insulated cables