Statement:
* conductor for the multi-annealing bare copper or tin plated copper strands
* PVC insulation
* PVC jacket
* film around the moisture-proof package
* tin copper braided shield
Use:
This applies to the wild product lines. Electrical Instrument telecommunications broadcasting, electronic equipment and automation devices, such as shielding lines.
The use of temperature:
* The length of wire to allow temperature is more than 70 ¡æ
* The laying of the cable, not lower than the temperature of -15 ¡æ
* Relative Humidity: 98%
Main technical parameters:
* rated voltage (AC 50 Hz): 380V DC: 500 V
* test voltage (AC 50 Hz): 2000V
* insulation resistance (20 ¡æ): not less than 2 M ¦¸ km
* braided wire and cable general density of not less than 80 percent
Implementation of the standards:
JB 8734-1998 JIS C3662
JB 5023-1997 DIN VDE 0281
EC 227
Model:
1.AVVR structural parameters
2.AVVR-300/300V Copper core PVC insulated cables
3.AVPV / SBVVP Copper core PVC insulated cables
4.AVPV SBVVP Copper core PVC insulated cables
5.AVR Copper core PVC insulated cables
6.AVRS Copper core PVC insulated cables